- Added the “Edit field” graphic element to the website.
- We are considering creating a configurable interface to edit recipes at runtime. Contact support if you have any suggestions or comments.
Sunday, May 13, 2018
HMI update 05/13/2018
Thursday, April 26, 2018
Software update 04/26/2018
- Added the bar code graphic element to the website.
- Corrected an issue with the pipe tool editor.
- Added a few more commands to the DF1 slave simulator.
- Added a “fixed” position property to the website graphic elements. The default position value is “absolute”.
Thursday, April 19, 2018
HMI update 04/19/2018
The analog and digital points can now be configured for a secondary data source.
Example:
A PLC has a MODBUS TCP (Ethernet) connection and also a MODBUS RTU (RS-232, serial) connection.
A primary port (A) is configured for the TCP connection and a secondary port (B) is configured for the RTU connection.
Points (PP) are created using the primary port (A) as a source.
Points (SP) are created using the secondary port (B) as a source.
All the primary points (PP) are configured to access the appropriate secondary point (SP).
Graphics, logging, alarms are all configured for the primary points (PP).
The secondary points (SP) do not process alarms and should not be configured for other access.
The secondary points (SP) are only used in the primary point (PP) configuration.
Should the primary port (A) experience a communication failure the data collected by the secondary points (SP) is used as the data for the primary points (PP) until the primary port (A) communication failure is corrected.
Example:
A PLC has a MODBUS TCP (Ethernet) connection and also a MODBUS RTU (RS-232, serial) connection.
A primary port (A) is configured for the TCP connection and a secondary port (B) is configured for the RTU connection.
Points (PP) are created using the primary port (A) as a source.
Points (SP) are created using the secondary port (B) as a source.
All the primary points (PP) are configured to access the appropriate secondary point (SP).
Graphics, logging, alarms are all configured for the primary points (PP).
The secondary points (SP) do not process alarms and should not be configured for other access.
The secondary points (SP) are only used in the primary point (PP) configuration.
Should the primary port (A) experience a communication failure the data collected by the secondary points (SP) is used as the data for the primary points (PP) until the primary port (A) communication failure is corrected.
Tuesday, March 20, 2018
HMI update 03/20/2018
·
Added
support for the diagnostic status command to the DF1 simulator.
· Added the scale graphic element to the website.
· Added the video player graphic element to the website.
· Added the scale graphic element to the website.
· Added the video player graphic element to the website.
Wednesday, February 21, 2018
HMI update 02/21/2018
- Added an analog clock graphic element to the website.
- Added a mini trend graphic element to the website.
- Resolved a rare issue with closing the configuration program and the window list editor open, with unsaved files.
- Added the marquee graphic element to the website.
Sunday, January 14, 2018
First HMI update for 2018
This update is, mainly, for the BACnet/IP driver. The BACnet/IP driver
was created about seven years ago and has now been updated to provide some of the
features of the newer drivers.
·
Added character string data type support.
·
Added unsigned data type support.
·
Added
writing a “Null” to an object.property.
·
Added
additional error reporting.
·
Added a script
command to write to any object property. This is to write to properties not
configured as points and to write a “Null” to a property.
·
Added a helper
to create BACnet script write commands.
·
A point/string
testing window was added to the BACnet/IP configuration editor.
Thursday, December 28, 2017
HMI update 12/28/2017
·
Added additional diagnostics for the WeMo port type.
· Changed the "new" version download logic to support SSL.
· During configuration the AB Logix port can now fetch the tags from the controller and generate points. L5K import continues to be supported.
· Corrected an issue were license dates newer (> 400 days) than the program date reported a license expired message.
· Happy New Year
· Changed the "new" version download logic to support SSL.
· During configuration the AB Logix port can now fetch the tags from the controller and generate points. L5K import continues to be supported.
· Corrected an issue were license dates newer (> 400 days) than the program date reported a license expired message.
· Happy New Year