- Added an analog clock graphic element to the website.
- Added a mini trend graphic element to the website.
- Resolved a rare issue with closing the configuration program and the window list editor open, with unsaved files.
- Added the marquee graphic element to the website.
Wednesday, February 21, 2018
HMI update 02/21/2018
Sunday, January 14, 2018
First HMI update for 2018
This update is, mainly, for the BACnet/IP driver. The BACnet/IP driver
was created about seven years ago and has now been updated to provide some of the
features of the newer drivers.
·
Added character string data type support.
·
Added unsigned data type support.
·
Added
writing a “Null” to an object.property.
·
Added
additional error reporting.
·
Added a script
command to write to any object property. This is to write to properties not
configured as points and to write a “Null” to a property.
·
Added a helper
to create BACnet script write commands.
·
A point/string
testing window was added to the BACnet/IP configuration editor.
Thursday, December 28, 2017
HMI update 12/28/2017
·
Added additional diagnostics for the WeMo port type.
· Changed the "new" version download logic to support SSL.
· During configuration the AB Logix port can now fetch the tags from the controller and generate points. L5K import continues to be supported.
· Corrected an issue were license dates newer (> 400 days) than the program date reported a license expired message.
· Happy New Year
· Changed the "new" version download logic to support SSL.
· During configuration the AB Logix port can now fetch the tags from the controller and generate points. L5K import continues to be supported.
· Corrected an issue were license dates newer (> 400 days) than the program date reported a license expired message.
· Happy New Year
Saturday, October 28, 2017
HMI update 10/28/2017
· Added script command to set mouse pointer position.
· Added script
command to convert unit types. For example from inches to centimeters. Area, distance,
temperature, volume, time and mass unit types are supported.
· Added
sixteen segment graphic element to the website feature.
· Added
“PointExist” script command.
· Added
property to expose HMI version string to script engine.
· Added a
script command to get/set the position/size of an open user window.
· Added a
default error image for display when a camera image capture failed.
· Added a
video group graphic element (website) to use one connection per group of cameras.
Friday, September 1, 2017
HMI update 9/1/2017
· Added two script commands to return additional computer information.
· Changed the
animation configuration dialog to allow the animations to be listed in a single
column. This required panel reordering.
· Added an
alarm indictor to display a rectangle and/or a symbol if a tag connected to the
graphic element is in alarm.
· An ODBC
recipe can be configured for a row as the recipe or a column as a recipe.
· Added
LoadRecipe2 script command to support ODBC recipe enhancements.
· Added a
DBGraphicRead script command to get the current text of the database memo,
edit, text, list box, drop list and check box control into a script.
· Added some
protection code for the dynamic image graphic animation.
Monday, August 7, 2017
HMI update 8/7/2017
Saturday, July 29, 2017
Updates 7/29/2017...
· The free PeakHMI MODBUS TCP slave simulator was updated to support a 1 or 2 byte
slave ID.
· A new TCP MODBUS master port type was added to the HMI. The new port
type can use a 1 or 2 byte slave ID.
Subscribe to:
Posts (Atom)